(a)Electric cables and signaling cables. A single application may
address two or more sizes, types, and constructions if the products do not
differ in composition of materials or basic design. Applications shall
include the following information for each product:
(1) Product information:
(a)(1)(i) Cable type (for example, G or G--GC).
(a)(1)(ii) Construction (for example, round or flat).
(a)(1)(iii) Number and size (gauge) of each conductor.
(a)(1)(iv) Voltage rating for all cables containing electric
conductors.
(a)(1)(v) For electric cables, current-carrying capacity of
each conductor, with corresponding ambient temperature upon which the current
rating (ampacity) is based, of each power conductor.
(2) Design standard. Specify any published consensus
standard used and fully describe any deviations from it, or fully describe
any nonstandard design used.
(3) Materials. Type and identifying numbers for each
material comprising the finished assembly.
(b)Splice kit. A single application may address two or more sizes,
types, and constructions if the products do not differ in composition of
materials or basic design. Applications shall include the following
information for each product:
(1) Product information:
(b)(1)(i) Trade name or designation (for example, style or
code number).
(b)(1)(ii) Type or kit (for example, shielded or
nonshielded).
(b)(1)(iii) Voltage rating.
(2) Design standard. Specify any published design
standard used and fully describe any deviations from it, or provide complete
final assembly dimensions for all components for each cable that the splice
kit is designed to repair.
(3) Materials. Type of materials, supplier, supplier's
stock number or designation for each component.
(4) Complete splice assembly instructions which clearly
identify all components and detail procedures used in making the splice.