(a)Test procedures. (1) The contact resistance through each
firing line terminal shall be determined.
(2) A 10-pound pull shall be applied to a No. 18 gauge
wire that has been connected to each firing line terminal according to the
manufacturer's instructions.
(b)Acceptable performance. (1) The contact resistance shall
not be greater than 1 ohm.
(2) The No. 18 gauge wire shall not become disconnected
from either firing line terminal.