| Find It! in DOL | Compliance Assistance | |
30 CFR § 56.6602 Static electricity dissipation during loading. When explosive material is loaded pneumatically into a blasthole in a manner that generates a static electricity hazard-- (a) An evaluation of the potential static electricity hazard shall be made and any hazard shall be eliminated before loading begins; (b) The loading hose shall be of a semiconductive type, have a total of not more than 2 megohms of resistance over its entire length and not less than 1000 ohms of resistance per foot; (c) Wire-countered hoses shall not be used; (d) Conductive parts of the loading equipment shall be bonded and grounded and grounds shall not be made to other potential sources of extraneous electricity; and (e) Plastic tubes shall not be used as hole liners if the hole contains an electric detonator. |
|
|