[Notices]
[Page 56180-56181]
-----------------------------------------------------------------------
DEPARTMENT OF LABOR
Mine Safety and Health Administration
Petitions for Modification
The following parties have filed petitions to modify the application of existing safety standards under section 101(c) of the Federal Mine Safety and Health Act of 1977 and 30 CFR part 44.
1. Excel Coal Company
[Docket No. M-2006-057-C]
Excel Coal Company, RD
2. Excel Coal Company
[Docket No. M-2005-058-C]
Excel Coal Company, RD
3. Excel Coal Company
[Docket No. M-2006-059-C]
Excel Coal Company, RD
4. Excel Coal Company
[Docket No. M-2006-060-C]
Excel Coal Company, RD
5. Big River Mining, LLC
[Docket No. M-2006-061-C]
Big River Mining, LLC, P.O. Box 186, New Haven, West Virginia 25626 has filed a petition to modify the application of 30 CFR 75.900 (Low- and medium-voltage circuits serving three-phase alternating current equipment; circuit breakers) to its Broad Run Mine (MSHA I.D. No. 46- 09136) located in Mason County, West Virginia. The petitioner proposes to use a contactor in certain locations in series with the circuit breaker. The petitioner states that: (1) The contactors are designed and rated for switching and will switch a great number of times more than a circuit breaker without failure and are more reliable than circuit breakers for switching when used within their rating; (2) many of the installations use a circuit breaker in series with a contactor, but Big River Mining would like to use the circuit breaker for short circuit; (3) the contactor may be equipped to provide undervoltage, grounded phase protection, overload protection, and other protective functions normally provided by the circuit breaker; and (4) the contactors would provide undervoltage, grounded phase, overload, and monitor the grounding conductors for low- and medium-voltage power circuits serving three-phase alternating current equipment using the following special terms and conditions: (a) The nominal voltage of the power circuits(s) will not exceed 995 volts; (b) the nominal voltage of the control circuit(s) and audible alarms units will not exceed 120 volts; and (c) the contactor will be built into the same enclosure as the circuit breakers. Further details of the terms and conditions are listed in the petition for modification and are available upon request. The petitioner further states that the proposed alternative method would not be implemented until all qualified persons who perform work on the equipment and the circuits have received training in the safe maintenance procedures and terms and conditions of the Proposed Decision and Order. The petitioner asserts that the proposed alternative method would provide at least the same measure of protection as the existing standard.
6. Round Mountain Gold Corporation
[Docket No. M-2006-005-M]
Round Mountain Gold Corporation, P.O. Box 480, Round Mountain, Nevada 89045 has filed a petition to modify the application of 30 CFR 56.6309(b) (Fuel oil requirements for ANFO) to its Smoke Valley Common Operation (MSHA I.D. No. 26-00594) located in Nye County, Nevada. The petitioner proposes to install a commercially manufactured system (a Doerschneider oil blender) specifically engineered to blend recycled oil with diesel fuel in the manufacturing process for ANFO. The resulting blend of recycled oils and diesel fuel will be used to manufacture ammonium nitrate-fuel oil (ANFO) for blasting. Further details of the terms and conditions are listed in the petition for modification and are available upon request. The petitioner asserts that the proposed alternative method would provide at least the same measure of protection as the existing standard.
Request for Comments
Persons interested in these petitions are encouraged to submit comments via e-mail to Standards-Petitions@dol.gov. Include ``petitions for modification'' in the subject line of the e-mail. Comments can also be submitted by fax, regular mail, or hand-delivery. If faxing your comments, include ``petitions for modification'' on the subject line of the fax. Comments by regular mail or hand-delivery should be submitted to the Mine Safety and Health Administration, Office of Standards, Regulations, and Variances, 1100 Wilson Boulevard, Room 2350, Arlington, Virginia 22209. If hand-delivered, you are required to stop by the 21st floor to check in with the receptionist. All comments must be postmarked or received by the Office of Standards, Regulations, and Variances on or before October 26, 2006. Copies of the petitions are available for inspection at that address.
Dated at Arlington, Virginia this 19th day of September 2006.
Ria Moore Benedict,
Deputy Director, Office of Standards, Regulations, and Variances.
[FR Doc. 06-8248 Filed 9-25-06; 8:45 am]
BILLING CODE 4510-43-P
