What's New for June 2009
POSTED: 06/03/2009
Mine Emergency Response Development (Merd) Contest Guidelines
The Mine Emergency Response Development (MERD) exercise contest guidelines provide for the development of MERD exercises that will fulfill the requirements of a mine rescue contest for the purpose of 30 C.F.R. §49.60. A local mine rescue contest is training that provides an objective evaluation of demonstrated mine rescue team skills and can be a MERD exercise or a practical simulation exercise, such as a fire or explosion drill, where the team participates in simulated mine rescue team exercises and wears breathing apparatus. |
POSTED: 06/02/2009
Equipment Alert Posted
Bucyrus 848 Un-A-Haulers
The automatic emergency-parking brakes on some Bucyrus 848 Un-A-Haulers may take 4 to 5 seconds to activate after the panic bar is hit. When this type of equipment is field tested, the brake must engage within one second after hitting the panic bar. As a precaution, the 848 Un-A-Haulers should be field tested to determine if the brakes activate immediately (within one second) when the panic bar is hit as required by 30 CFR 75.523-3(b)(1).
|
POSTED: 06/04/2009
PIB09-09
Program Information Bulletin - Re-Issue P07-04 - Clarification of Requirements of Title 30 Code of Federal Regulations §57.11050 Escapeways and refuges |
POSTED: 06/04/2009
Fatal Accident Report Posted
Fatality #28 - December 11, 2008 - Machinery - Facility - Kentucky - Warrior Coal, LLC - Warrior Preparation Plant |
POSTED: 06/05/2009
I09-V-2
Procedure Instruction Letter - Use of Digital Cameras and the Storage and Preservation of Digital Images |
POSTED: 06/05/2009
PIB09-10
Program Information Bulletin - Re-Issue of P00-11 - Nondestructive Testing of Wire Rope -Electromagnetic Testing |
POSTED: 06/08/2009
Equipment Alert Posted
Fluke Digital Clamp Meters
In cooperation with the U.S. Consumer Product Safety Commission, Fluke is voluntarily recalling certain 333, 334, 335, 336 and 337 Digital Clamp Meters that were manufactured between January 29, 2008 and February 27, 2009. The models and serial numbers affected are listed in the poster provided above.
|
POSTED: 06/08/2009
FedReg E9-13173
Petition for Modification - Notice of petitions for modification of existing mandatory
safety standards. |
POSTED: 06/08/2009
Press Release Posted
MSHA kicks off safety initiative to focus on roof fall fatalities
More roof falls occur during summer months |
POSTED: 06/09/2009
FedReg. E9-13585
Proposed Rule; notice of public hearing; re-opening of comment
Coal Mine Dust Personal Monitors |
POSTED: 06/18/2009
P09-V-3
Program Policy Letter - Re-Issue P06-V-11 - Family Liaison and Primary Communicator: Implementation of Section 7 of the Mine Improvement and New Emergency Response Act of 2006 |
POSTED: 06/18/2009
I09-V-4
Procedure Instruction Letter - Re-Issue I06-V-11 - Mine Safety and Health Administration (MSHA) Procedures for Properly Identifying Equipment in Official Agency Document |
POSTED: 06/18/2009
I09-V-3
Procedure Instruction Letter - Procedures for Implementing the Mine Plan Approval Database System |
POSTED: 06/18/2009
News Release
MSHA publishes final rule for underground coal mine rescue teams
New rule calls for more teams, additional training |
POSTED: 06/18/2009
Dump-Point Layout
MSHA's Accident Prevention Program - Safety Idea |
POSTED: 06/18/2009
Fatal Accident Report Posted
Fatality #24 - October 19, 2008 - Powered Haulage - Underground - West Virginia - McElroy Coal Company - McElroy Mine |
POSTED: 06/30/2009
Fatal Accident Report Posted
Fatality #23 - February 29, 2008 (Determined Chargeable 05/06/2009) - Fall of Person - Texas - Limestone (C&B) - Maverick Materials LLC - Maverick Materials LLC |
POSTED: 06/30/2009
FedReg. E9-15258
Brookwood-Sago Mine Safety Grants - Notice of funding and priorities for fiscal year 2009. |
|