Skip to content
Mine Safety and Health Administration
Fuses That Provide Protection in Compliance With
75.1910 (a), (b), (c), (d), (e), and (f)




Mitsubishi

 

Mitsubishi

Approval

Number

 

System

 

Fuses

Circuit Breakers

AIRPAX

Carlingswitch

S4S

07-ENA030001

12 Volt; One HD 1000CCA Battery, No. 1 AWG Cables

Bussmann FRS-R-150

Ferraz Shawmut TRS-150RDC

Littelfuse FLSR-150A

JLE-1-30453-2

FA1-X0-09-644-32A-BG

S4Q2

07-ENA040013

12 Volt; One HD 1000CCA Battery, No. 1 AWG Cables

Bussmann FRS-R-150

Ferraz Shawmut TRS-150RDC

Littelfuse FLSR-150A

JLE-1-30453-2

FA1-X0-09-644-32A-BG

S4S-DT

07-ENA050001

12 Volt; One HD 1000CCA Battery, No. 1 AWG Cables

Bussmann FRS-R-150

Ferraz Shawmut TRS-150RDC

Littelfuse FLSR-150A

JLE-1-30453-2

FA1-X0-09-644-32A-BG


Notes:

1. - A single battery system on the Cummins engine is very prone to nuisance tripping. The two battery system yields better performance.

2 - Caution - Only the circuit breakers and fuses listed have been evaluated for operation with the listed engine and battery system. The time-current curve for each application must be examined. Circuit breakers or fuses cross-referenced to replacement brands may not meet the requirements of 30CFR 75.1910(a), 75.1910(b), 75.1910(c), 75.1910(d), 75.1910(e), and 75.1910(f).

3 AIRPAX and Carlingswitch circuit breakers are distributed by Generator Starter Service, P.O. Box 155, 50 East Center, Aurora, UT 84620. Phone (435) 529-7875.

4 - Carlingswitch circuit breakers are distributed by Alpha Services, Inc., P. O. Box 1045, Marion, IL 62959. Phone (618) 997-9999.