Skip to content
Mine Safety and Health Administration
Fuses That Provide Protection in Compliance With
75.1910 (a), (b), (c), (d), (e), and (f)




Caterpillar

 

 

Caterpillar

Approval

Number

 

Battery System

 

Fuses

Circuit Breakers

AIRPAX

Carlingswitch

3304 PCNA

7E-A003

7E-B004

12 Volt; 2-Parallel 1155CCA Batteries in One Tray, 1/0 AWG Cables

Bussmann FRS-R-150

Ferraz Shawmut TRS-150RDC

Littelfuse FLSR-150A

JLE-1-30453-2

FA1-X0-09-644-32A-BG

3304 PCNA

7E-A003

7E-B004

24 Volt; 2-Series 1155CCA Batteries in One Tray, 1/0 AWG Cables

Bussmann FRS-R-125

Ferraz Shawmut TRS-125RDC

Littelfuse FLSR-125A

JLE-1-30453-1

FA1-X0-09-645-32A-BG

3306 PCNA

7E-A002

7E-B003

24 Volt; 2-Series 1155CCA Batteries in One Tray, 1/0 AWG Cables

Bussmann FRS-R-150

Ferraz Shawmut TRS-150RDC

Littelfuse FLSR-150A

JLE-1-30453-2

FA1-X0-09-644-32A-BG

3306 DITA

7E-B010

12 Volt; 2-Parallel 1300CCA Batteries in One Tray, 1/0 AWG Cables

Bussmann FRS-R-175

Ferraz Shawmut TRS-175RDC

Littelfuse FLSR-175A

JLE-1-30453-3

FA1-X0-09-673-32A-BG

3306 DITA

7E-B010

24 Volt; 2-Series 1300CCA Batteries in One Tray, 1/0 AWG Cables

Bussmann FRS-R-175

Ferraz Shawmut TRS-175RDC

Littelfuse FLSR-175A

JLE-1-30453-3

FA1-X0-09-673-32A-BG

3406E ATTA

7E-B018

24 Volt; 2-Series 4D 1000CCA Batteries in One Tray, 1/0 AWG Cables

Bussmann FRS-R-200

Ferraz Shawmut TRS-200RDC

Littelfuse FLSR-200A

JLE-1-30453-4

FA1-X0-09-674-32A-BG

3056 PCNA

7E- B066

12 Volt; One HD 1000CCA Battery, 1/0 AWG Cables

Bussmann FRS-R-125

Ferraz Shawmut TRS-125RDC

Littelfuse FLSR-125A

JLE-1-30453-1

FA1-X0-09-645-32A-BG

3056 PCNA

7E- B066

24 Volt; 2 Series HD 1000CCA Batteries in One Tray, 1/0 AWG Cables

Bussmann FRS-R-100

Ferraz Shawmut TRS-100RDC

Littelfuse FLSR-100A

209-130547-4-V

FA1-X0-09-675-32A-BG

Notes:

1. - A single battery system on the Cummins engine is very prone to nuisance tripping. The two battery system yields better performance.

2 - Caution - Only the circuit breakers and fuses listed have been evaluated for operation with the listed engine and battery system. The time-current curve for each application must be examined. Circuit breakers or fuses cross-referenced to replacement brands may not meet the requirements of 30CFR 75.1910(a), 75.1910(b), 75.1910(c), 75.1910(d), 75.1910(e), and 75.1910(f).

3 AIRPAX and Carlingswitch circuit breakers are distributed by Generator Starter Service, P.O. Box 155, 50 East Center, Aurora, UT 84620. Phone (435) 529-7875.

4 - Carlingswitch circuit breakers are distributed by Alpha Services, Inc., P. O. Box 1045, Marion, IL 62959. Phone (618) 997-9999.