2/5/25
In the matter of Petition for Modification
Banner Blue Coal Company, LLC
Paw Paw 2 South Mine
I.D. No. 44-07401 Docket No. M-2024-005-C
PROPOSED DECISION AND ORDER
On April 10, 2024 a petition was filed seeking a modification of the application of 30 Code of Federal Regulations (30 C.F.R.) § 75.500(d) to Petitioner’s Paw Paw 2 South Mine, Paw Paw 2 Mine, and Shop Br. Mine located in Buchanan County, Virginia, and Pike County, Kentucky. The Petitioner alleges that the alternative method outlined in the petition will at all times guarantee no less than the same measure of protection afforded by the standard.
The petitioner included the Shop Br. (MSHA ID 15-19866) and the Paw Paw 2 (MSHA ID 15-19842) mines as part of this petition for modification. However, the operator informed MSHA that the Shop Br. Mine has since been transferred to another operator and the Paw Paw 2 Mine has been abandoned. Therefore, only the Paw Paw 2 South Mine will be included as part of this proposed decision and order.
The petitioned standard, 30 Code of Federal Regulations (30 C.F.R.) § 75.500(d) states, in relevant part,
(d) All other electric face equipment which is taken into or used inby the last open crosscut of any coal mine…..shall be permissible.
The Petitioner is requesting a modification of the standard to allow the use of non- permissible surveying equipment in or inby the last open crosscut.
MSHA personnel conducted an investigation of the petition and filed a report of their findings with the Administrator for Mine Safety and Health Enforcement. After careful review of the entire record, including the petition, and MSHA’s investigative report, this Proposed Decision and Order is issued.
Finding of Fact and Conclusion of Law
On September 12, 2024, an onsite inspection of the electronic surveying equipment to be used was conducted by Loren Tolliver (MSHA) accompanied by Stephen Maxfield (Director of Engineering) to determine the functionality of the proposed non-permissible surveying equipment.
Paw Paw 2 South Mine produces bituminous coal from the Splashdam coal bed. The average mining height is approximately 48 inches and has four producing mechanized mining units, with two on each working section. These MMUs produce approximately 1500 tons of coal daily. The mine employs 109 coal miners. Approximately 106 miners will be affected by this petition. Paw Paw 2 South is currently in active status and operates two production shifts per day, nine hours per shift, five days per week and has one maintenance shift per day. The mine liberates 95,793 cubic feet of methane in a 24-hour period, based on air sample results collected on April 18, 2024. Paw Paw 2 South has five portals ventilated by one Jefferey 8 1500 H.P. blowing fan.
On September 4, 2024, comments were solicited from twelve (12) supervisors and 73 miners from day and evening shifts. On September 5, 2024, comments were solicited from four (4) supervisors and 20 miners from the night shift. All supervisors and miners contacted had no issue with the use of the battery powered, non-permissible surveying equipment being used or taken into the last open crosscut of the mine.
Banner Blue Coal Company, Paw Paw 2 South Mine is a non-union operation, is not represented by a labor organization and does not have a representative of the miners. This petition is posted on the mine bulletin board.
Banner Blue Coal Company proposes the following alternative method to comply with 30 C.F.R. § 75.500(d).
1. Surveying equipment shall consist of battery-powered non-permissible total stations and theodolites with an ingress protection rating for dust and water resistance at a minimum of IP 66.2. Surveying Instruments proposed are Sokkia Digital Theodolite DT 950 LG/PS And/or Stonex R1 Plus.
3. A logbook will be maintained for the battery-powered non-permissible surveying equipment documenting the manufacturer, model number, date of manufacture or purchase. The logbook will be maintained at the mine office with other logbooks. The logbooks shall be made available to MSHA for inspection upon request.
4. The battery-powered non-permissible surveying equipment shall be examined by the person to operate the equipment prior to taking the equipment underground to ensure the equipment is being maintained in a safe operating condition.
These examinations shall include:
a. Check the instrument for any physical damage and the integrity of the case;
b. Remove the battery and inspect for corrosion;
c. Inspect the contact points to ensure a secure connection to the battery;
d. Reinstall the battery and power up and shut down to ensure proper connections; and
e. Check the battery compartment cover or battery attachment to ensure that it is securely fastened.
f. The results of this examination will be recorded in the logbook.
5. The equipment shall be examined at least weekly by a qualified person as defined in 30 CFR § 75.153. The examination results shall be recorded weekly in the equipment's logbook. Examination entries in the logbook may be expunged after one year.
6. The battery-powered non-permissible surveying equipment shall be serviced in accordance with the manufacturer's recommendations. Dates of service and a description of the service shall be recorded in the logbook.
7. The battery-powered non-permissible surveying equipment shall not be put in service at the mine until MSHA has inspected the equipment and determined that it is in compliance with all the requirements of this petition.
8. All areas to be surveyed must be pre-shifted according to 30 CFR § 75.360 prior to surveying. If the area was not pre-shifted, a supplemental examination according to 30 CFR § 75.361 must be performed before any non-certified person enters the area. If the area has been examined according to 30 CFR § 75.361, additional examination is not required.
9. Prior to energizing any of the non-permissible surveying equipment in or inby the last open crosscut, methane tests must be made in accordance with 30 CFR §75.323(a).
10. A qualified person as defined in existing 30 CFR § 75.151 shall continuously monitor for methane immediately before and during the use of nonpermissible surveying equipment in or inby the last open crosscut. A second person in the surveying crew, if there are two people in the crew, must also continuously monitor for methane. That person must either be a qualified person as defined in 30 CFR § 75.151 or be in the process of being trained to be a qualified person but has yet to "make such tests for a period of 6 months" as required by 30 CFR § 75.151. Upon completion of the 6-month training period the second person on the surveying crew must become qualified in order to continue on the surveying crew. If the surveying crew consists of one person, rather than two, such person shall monitor for methane with two separate devices.
11. All hand-held methane detectors shall be MSHA approved and maintained in permissible and proper operating condition as defined by 30 CFR § 75.320. All methane detectors must provide visual and audible warnings when methane is detected at or above 1.0 percent.
12. The battery-powered non-permissible surveying equipment shall not be used if methane concentrations at or above 1.0 percent is detected. When methane concentrations at or above 1.0 percent is detected while the equipment is being used, the equipment shall be de-energized immediately and withdrawn outby the last open crosscut. Prior to being taken into or inby the last open crosscut all the requirements of 30 CFR § 75.323 for excess methane shall be complied with.
13. Personnel engaged in the use of surveying equipment shall be properly trained to recognize the hazards and limitations associated with the use of surveying equipment in areas where methane could be present.
14. When using battery-powered non-permissible electronic surveying equipment in or inby the last open crosscut, the surveyor shall confirm by inquiry of the person in charge of the section, that the air quantity on the section, on that shift, in the last open crosscut is at least the minimum quantity that is required by the mine's ventilation plan.
15. A safety check will be performed by the surveyor(s), prior to setting up and energizing non-permissible electronic equipment in or inby the last open crosscut of any coal mine. The surveyor(s) shall conduct a visual examination of the immediate area for evidence that the areas appear to be sufficiently rock dusted and for the presence of accumulated float coal dust. If the rock-dusting appears insufficient or the presence of accumulated float coal dust is observed, the equipment may not be energized until sufficient rock dust has been applied and/or the accumulations of float coal dust have been cleaned up.
16. Batteries contained in the surveying equipment must be "changed out" in the intake air outby the last open crosscut. Replacement batteries for the electronic surveying equipment shall be carried only in the compartment provided for a spare battery in the electronic equipment carrying case. Before each shift of surveying, all batteries for the electronic surveying equipment must be charged sufficiently such that they are not expected to be replaced on that shift. Lithium ion batteries shall not be charged underground. Lithium ion batteries shall only be charged on the surface area of the underground mine.
17. All members of the surveying crew using battery-powered non-permissible surveying equipment shall receive specific training on the terms and conditions of this plan prior to using the equipment in or inby the last open crosscut. A record of the training shall be kept with the other training records.
18. Within 60 days after final approval, the operator shall submit proposed revisions for its approved 30 CFR § 48 training plan to the Coal Mine Safety and Health District Manager. These proposed revisions shall specify initial and refresher training regarding the terms and conditions stated in this Petition. The training will be documented on a MSHA certificate of Training (Form 5000-23). Comments shall be included on the Certificate of Training indicating that surveying training was completed.
19. Battery-powered non-permissible theodolites (Sokkia DT 950 LG/PS) shall not be taken or used inby the last crosscut of the coal mine after it is five (5) years old. Battery-powered total stations (Stonex R1 Plus) shall not be taken or used inby the last crosscut of the coal mine after it is ten (10) years old. The operator will maintain a cycle of purchasing new electronic surveying equipment whereby theodolites will be no older than five years from the date of manufacture and total stations and other electronic surveying equipment will be no older than 10 years from the date of manufacture.20. Any surveying contractors hired by the operator that are using electronic equipment shall do so in accordance with the requirements of Condition Number 18 above. The conditions of use in this Petition shall apply to all non-permissible electronic surveying equipment used in or inby the last open crosscut regardless of whether the equipment is used by the operator or by an independent contractor.21. Battery-powered non-permissible surveying equipment may be used when production is occurring, subject to these conditions:
a. On an MMU where production is occurring, non-permissible electronic surveying equipment shall not be used downwind of the discharge point of any face ventilation controls, such as tubing (including controls such as "baloney skins") or curtains.
b. Production may continue while non-permissible electronic surveying equipment is used, if the surveying equipment is used in a separate split of air from where production is occurring.
c. Non-permissible surveying equipment shall not be used in a split of air ventilating an MMU if any ventilation controls will be disrupted during such surveying. Disruption of ventilation controls means any change to the mine's ventilation system that causes the ventilation system not to function in accordance with the mine's approved ventilation plans.
d. If, while surveying, a surveyor must disrupt ventilation, the surveyor shall cease surveying and communicate to the section foreman that the ventilation must be disrupted. Production must stop while ventilation is disrupted. Ventilation control must be reestablished immediately after the disruption is no longer necessary. Production can only resume after all ventilation controls are reestablished and are in compliance with approved ventilation or other plans, and other applicable laws, standards, or regulations.
e. Any disruption in ventilation shall be recorded in the logbook required by this order. The logbook shall include a description of the nature of the disruption, the location of the disruption, the date and time of the disruption, the date and time the surveyor communicated the disruption to the section foreman, the date and time production ceased, the date and time ventilation was reestablished and the date and time production resumed.
f. All surveyors, section foreman, section crew members and other personnel who will be involved with or affected by surveying operations shall receive training in accordance with 30 CFR § 48.7 on the requirements of this Plan within 60 days of final approval. Such training must be completed before any non-permissible surveying equipment can be used while production is occurring. The operator shall keep a record of such training and provide such record to MSHA upon request.
g. The operator shall provide annual retraining to all personnel who will be involved with or affected by surveying operations in accordance with 30 CFR § 48.8. The operator shall train new miners on the requirements of this Plan in accordance with 30 CFR § 48.6. The operator shall keep a record of such training and provide such record to MSHA upon request.
22. This Petition shall be posted in unobstructed locations on the bulletin boards and/or in other conspicuous places where notices to miners are ordinarily posted at the mine for a period of not less than 60 consecutive days.
All non-permissible electronic total stations and theodolites shall have an IP 66 or greater rating as stipulated in the Consent Order signed by the Assistant Secretary on September 21, 2018, that established terms and conditions to safely use non- permissible electronic surveying equipment in gassy areas. When equipment contains lithium batteries, the equipment must meet lithium battery safety standard UL1642 or IEC 62133.
The petitioner provided specification data for the proposed surveying equipment which indicates that the Digital Theodolite DT 950 LG/PS utilizes four (4)- AA Alkaline dry cell batteries or a BDC71 Lithium Ion Battery, and the Stonex R1 Plus total station utilizes a rechargeable 7.4 volt lithium-ion battery. The specification data indicates that both instruments have an ingress protection (IP) rating of 66. The district’s investigator examined the proposed surveying equipment. Therefore, the proposed instruments meet the criteria of “similar low voltage battery-operated” equipment as outlined in the Consent Order. The definition of “similar low voltage battery- operated” equipment, as used in the Consent Order, is based on the battery voltage not exceeding that of the surveying instruments listed in the Consent Order. MSHA determined that surveying instrument batteries of 8 volts or less are acceptable as “similar low voltage batteries”.
The petitioner states in Item 15, page 6 that “Batteries contained in the surveying equipment must be “changed out” in the intake air outby the last open crosscut”. Additionally, the petitioner states that “Lithium ion batteries shall not be charged underground. Lithium batteries shall only be charged on the surface area of the underground mine”.
The alternate method proposed by the Petitioner (and as amended herein by MSHA) will, at all times, guarantee no less than the same measure of protection afforded the miners under 30 C.F.R. § 75.500(d).
On the basis of the petition and the findings of MSHA’s investigation, Banner Blue Coal Company, is granted a modification of the application of 30 C.F.R. § 75.500(d) to the Paw Paw 2 South Mine.
ORDER
Wherefore, pursuant to the authority delegated by the Secretary of Labor to the Administrator for Mine Safety and Health Enforcement and pursuant to Section 101(c) of the Federal Mine Safety and Health Act of 1977, 30 U.S.C. § 811(c), it is ordered that Banner Blue Coal Company’s Petition for Modification of the application of 30 C.F.R. § 75.500(d) at the Paw Paw 2 South Mine is hereby:
GRANTED, for the operator who may use the following total stations and theodolites and similar low voltage (8 Volts or less) battery-operated total stations and theodolites if they have an IP rating of 66 or greater in or inby the last open crosscut, subject to the conditions of this Order:
The petitioner proposes to use the following low voltage battery-operated surveying equipment:
Manufacturer/Model: SOKKIA DIGITAL THEODOLITE DT 950 LG/PS
Batteries: 4 - AA Alkaline Dry Cell OR BDC71 Lithium-ion Volts: 7.2 V
Ingress Protection (IP) rating: IP66
Manufacturer/Model: STONEX R1 PLUS Battery: Rechargeable Lithium-ion
Volts: 7.4 V
Ingress Protection (IP) rating: IP66
1. Non-permissible electronic surveying equipment shall only be used until equivalent permissible electronic surveying equipment is available. The equipment allowed under this Order is a low voltage (8 volts or less) battery- powered non-permissible total station. All non-permissible electronic equipment shall have an IP 66 or greater rating. When equipment contains lithium batteries, the equipment must meet lithium battery safety standard UL1642 or IEC 62133. Manufacturer recommended battery packs must be used in all equipment.
2. The operator will maintain a logbook for electronic surveying equipment with the equipment, or in the location where mine record books are kept or in the location where the surveying record books are kept. The logbook will contain the date of manufacture and/or purchase of each particular piece of electronic surveying equipment and include proof of compliance with any lithium battery safety standard. The logbook shall be made available to MSHA upon request.
3. All non-permissible electronic surveying equipment to be used in or inby the last open crosscut, shall be examined by the person to operate the equipment prior to taking the equipment underground to ensure the equipment is being used according to the original equipment manufacturer’s recommendations and maintained in a safe operating condition. These examinations shall include:
i. Check the instrument for any physical damage and the integrity of the case;
ii. Remove the battery and inspect for corrosion;
iii. Inspect the contact points to ensure a secure connection to the battery;
iv. Reinsert the battery and power up and shut down to ensure proper connections; and
v. Check the battery compartment cover or battery attachment to ensure that it is securely fastened.
vi. For equipment utilizing lithium type cells, ensure that lithium cells and/or packs are not damaged or swelled in size.
The results of this examination will be recorded in the logbook.
4. The equipment shall be examined at least weekly by a qualified person as defined in 30 C.F.R. § 75.153; the examination results shall be recorded weekly in the equipment's logbook. Examination entries in the logbook may be expunged after one year.
5. The operator is to ensure that all non-permissible electronic surveying equipment is serviced according to the manufacturer's recommendations. Dates of service will be recorded in the equipment's logbook and shall include a description of the work performed.
6. The non-permissible surveying equipment that will be used in or inby the last open crosscut, shall not be put into service until MSHA has initially inspected the equipment and determined that it is in compliance with all the terms and conditions of this Order.
7. Non-permissible surveying equipment shall not be used if methane is detected in concentrations at or above 1.0 percent methane. When 1.0 percent or more of methane is detected while the non- permissible surveying equipment is being used, the equipment shall be de-energized immediately and the non- permissible electronic equipment withdrawn outby the last open crosscut.
Prior to entering in or inby the last open crosscut all requirements of 30 C.F.R. § 75.323 must be complied with.
8. As an additional safety check, prior to setting up and energizing non- permissible electronic surveying equipment in or inby the last open crosscut, the surveyor(s) shall conduct a visual examination of the immediate area for evidence that the area appears to be sufficiently rock- dusted and for the presence of accumulated float coal dust. If the rock- dusting appears insufficient or the presence of accumulated float coal dust is observed, the equipment may not be energized until sufficient rock dust has been applied and/or the accumulations of float coal dust have been cleaned-up. If non- permissible electronic surveying equipment is to be used in an un-rock dusted area within 40 feet of a working face where a continuous mining machine is used to extract coal, the area is to be rock dusted prior to energizing the electronic surveying equipment. A positive means of preventing mobile equipment from tramming in the same entry or crosscut where surveyors are conducting their work inby the feeder shall be provided and addressed in the Ventilation Plan.
9. All hand-held methane detectors shall be MSHA approved and maintained in permissible and proper operating condition as defined by 30 C.F.R. § 75.320. All methane detectors must provide visual and audible warnings when methane is detected at or above 1.0 percent.
10. Prior to energizing any of the non-permissible surveying equipment in or inby the last open crosscut, methane tests must be made in accordance with 30 C.F.R. § 75.323(a).
11. All areas to be surveyed must be pre-shifted according to 30 C.F.R. § 75.360 prior to surveying. If the area was not pre-shifted, a supplemental examination according to 30 C.F.R. § 75.361 must be performed before any non- certified person enters the area. If the area has been examined according to 30 C.F.R. § 75.360 or 30 C.F.R. § 75.361, additional examination is not required.
12. A qualified person as defined in existing 30 C.F.R. § 75.151 shall continuously monitor for methane immediately before and during the use of non- permissible surveying equipment in or inby the last open crosscut. A second person in the surveying crew, if there are two people in the crew, must also continuously monitor for methane. That person must either be a qualified person as defined in 30 C.F.R. § 75.151 or be in the process of being trained to be a qualified person but has yet to "make such tests for a period of 6 months" as required by 30 C.F.R. § 75.150. Upon completion of the 6-month training period the second person on the surveying crew must become qualified in order to continue on the surveying crew. If the surveying crew consists of one person, rather than two, such person shall monitor for methane with two separate devices.
13. Replacement batteries for the electronic surveying equipment shall be carried only in the compartment provided for a spare battery in the electronic equipment carrying case. Before each shift of surveying, all batteries for the electronic surveying equipment must be charged sufficiently so that they are not expected to be replaced on that shift. The “change out” of the battery packs shall only be performed in intake air outby the last open crosscut.
The following maintenance and use conditions shall apply to equipment containing lithium-type batteries:
i. The battery pack must not be disassembled or modified by anyone other than permitted by the manufacturer of the equipment.
ii. The battery pack must only be charged on the surface of the mine using the original equipment manufacturer’s recommended charger.
iii. The battery must not be exposed to water or allowed to get wet. This does not preclude incidental exposure of sealed battery packs.
iv. The battery must not be placed in direct sunlight or used or stored near a source of heat.
v. The battery must not be used at the end of its life cycle (e.g. when there is a performance decrease of greater than 20% in battery operated equipment). The battery must be disposed of properly.
a. Follow the manufacturer’s recommendations and instructions. Check and monitor each unit’s run time. Observe and note the run time that a new fully charged battery provides for powering the unit. Record and use this new battery run time as the baseline for determining its service life.
Note: The battery run time will vary depending on the product’s configuration and the applications running.
b. Routinely check the battery’s charge status.
c. Routinely monitor batteries that are approaching the end of their estimated service life.
d. Remove the battery from service with the following conditions:
i. The battery run time drops below about 80% of the new battery run time.
ii. The battery charge time increases significantly.
e. Follow the storage instructions as recommended by the manufacturer. If the instructions were not followed for a battery stored or otherwise unused for an extended period or the battery has no charge remaining, consider it to be damaged. Do not attempt to recharge it or to use it. Remove it from service and replace it with a new battery.
14. When using non-permissible electronic surveying equipment in or inby the last open crosscut, the surveyor must confirm by measurement or by inquiry of the person in charge of the section, that the air quantity on the section, on that shift, in the last open crosscut is at least the minimum quantity that is required by the mine's ventilation plan.
15. Personnel engaged in the use of surveying equipment shall be properly trained to recognize the hazards and limitations associated with the use of surveying equipment in areas where methane could be present.
16. All members of the surveying crew shall receive specific training on the terms and conditions of this Order before using non-permissible electronic equipment in or inby the last open crosscut. A record of the training shall be kept with the other training records.
17. Within 60 days after this Order becomes final, the operator shall submit proposed revisions for its approved 30 C.F.R. § 75.370(a)(1) ventilation plan and 30 C.F.R. Part 48 training plans to the Mine Safety and Health District Manager. These proposed revisions shall specify additional measures to protect surveyors from the hazards of mobile equipment while conducting their work on the working section, initial and refresher training regarding the terms and conditions stated in this Order. When training is conducted on the terms and conditions in this Order, an MSHA Certificate of Training (Form 5000-23) shall be completed. Comments shall be included on the Certificate of Training indicating that it was surveyor training.
18. The operator shall maintain a cycle of purchasing new electronic surveying equipment whereby theodolites will be no older than five years from the date of manufacture and total stations will be no older than ten years from the date of manufacture.
19. The operator is responsible for seeing that all surveying contractors hired by the operator are using electronic equipment in accordance with the requirements of Condition Number 18 in this Order.
The conditions of use in this Order shall apply to all non-permissible electronic surveying equipment used in or inby the last open crosscut regardless of whether the equipment is used by the operator or by an independent contractor.
20. Non-permissible surveying equipment may be used when production is occurring, subject to these conditions:
a. On an MMU where production is occurring, non- permissible electronic surveying equipment shall not be used downwind of the discharge point of any face ventilation controls, such as tubing (including controls such as baloney skins) or curtains.
b. Production may continue while non-permissible electronic surveying equipment is used, if the surveying equipment is used in a separate split of air from where production is occurring.
c. Non-permissible surveying equipment shall not be used in a split of
air ventilating an MMU if any ventilation controls will be disrupted during such surveying. Disruption of ventilation controls means any change to the mine's ventilation system that causes the ventilation system not to function in accordance with the mine's approved ventilation plan.
d. If, while surveying, a surveyor must disrupt ventilation, the surveyor shall cease surveying and communicate to the section foreman that ventilation must be disrupted. Production must stop while ventilation is disrupted. Ventilation controls must be reestablished immediately after the disruption is no longer necessary. Production can only resume after all ventilation controls are reestablished and are in compliance with approved ventilation or other plans, and other applicable laws, standards, or regulations.
e. Any disruption in ventilation shall be recorded in the logbook required by this Order. The logbook shall include a description of the nature of the disruption, the location of the disruption, the date and time of the disruption, the date and time the surveyor communicated the disruption to the section foreman, the date and time production ceased, the date and time ventilation was reestablished, and the date and time production resumed.
f. All surveyors, section foremen, section crew members, and other personnel who will be involved with or affected by surveying operations shall receive training in accordance with 30 C.F.R. § 48.7 on the requirements of this Order within 60 days of the date this Order becomes final. Such training must be completed before any non-permissible surveying equipment can be used while production is occurring. The operator shall keep a record of such training and provide such record to MSHA upon request.
g. The operator shall provide annual retraining to all personnel who will be involved with or affected by surveying operations in accordance with 30 C.F.R. § 48.8. The operator shall train new miners on the requirements of this Order in accordance with 30 C.F.R. § 48.5, and shall train experienced miners, as defined in 30 C.F.R. § 48.6, on the requirements of this Order in accordance with 30 C.F.R. § 48.6. The operator shall keep a record of such training and provide such record to MSHA upon request.
21. The operator shall post this Order in unobstructed locations on the bulletin boards and/or in other conspicuous places where notices to miners are ordinarily posted, for a period of not less than 60 consecutive days.
Unless specifically mentioned herein, nothing in this Order changes or supersedes the requirements otherwise imposed by the Mine Act, other mandatory standards or regulations, or approved ventilation or other plans.
The petitioner shall include the above terms and conditions in the initial and annual refresher training as required in its approved Part 48 training plans to ensure that miners are aware of the stipulations contained in this petition.
Any party to this action desiring a hearing on this matter must file in accordance with 30 C.F.R. § 44.14 within 30 days. The request for hearing must be filed with the Administrator for Mine Safety and Health Enforcement, 201 12th Street South, Suite 401, Arlington, Virginia 22202-5452.
If a hearing is requested, the request shall contain a concise summary of position on the issues of fact or law desired to be raised by the party requesting the hearing, including specific objections to the proposed decision.
A party other than the Petitioner who has requested a hearing may also comment upon all issues of fact or law presented in the petition and any party to this action requesting a hearing may indicate a desired hearing site. If no request for a hearing is filed within 30 days after service thereof, the Decision and Order will become final and must be posted by the operator on the mine bulletin board at the mine.
Brian Goepfert,
Administrator for
Mine Safety and Health Enforcement
Certificate of Service
I hereby certify that a copy of this proposed decision was served personally or
mailed, postage paid, or provided by other electronic means this 5 day of February, 2025
to:
Mr. Stephen E. Maxfield, P.E.
Director of Engineering for VA and KY 1073 Riverview St
Grundy, VA 24614 steve.maxfield@unitedcoal.com
Avichai Ozur Bass General Engineer
cc: Mr. M. Randy Moore, Director of Mine Safety, Virginia Energy 3405 Mountain Empire Road
Big Stone Gap, VA 24219 DmInfo@dmme.virginia.gov