Petition Docket No. M-2024-035-C

03/03/2025
In the matter of                     PETITION FOR MODIFICATION
Buchanan Minerals, LLC
Buchanan Mine #1, 
Mine I.D. No. 44-04856        Docket No. M-2024-035-C

PROPOSED DECISION AND ORDER

On August 28, 2024, Buchanan Minerals, LLC filed a petition seeking modification of the application of 30 C.F.R. § 75.507-l(a) at its Buchanan Mine #1 in Buchanan County, VA. The petitioner alleges that the alte1native method in the petition will at all times guarantee no less than the same measure of protection afforded to the miners by the standard.

The petitioned standard, 30 C.F.R. § 75.507-l(a) - Permissible electric equipment states,

All electric equipment, other than power-connection points, used in return air outby the last open crosscut in any coal mine shall be permissible except as provided in paragraphs (b) and (c) of this section.

The petitioner is requesting a modification of the standard to allow the use of unapproved Powered Air Purifying Respirators (PAPRs) in return air outby the last open. Specifically, the petitioner is requesting to utilize the 3M Versaflo TR-800 Intrinsically Safe (Versaflo TR-800) PAPR motor/blower and battery with batte1y pack. The CleanSpace EX PAPR was granted in a previous Proposed Decision and Order, Docket Number M-2021-023-C on January 28, 2022.

The petitioner states that:

1.    It previously used the MSHA-approved 3M Airstream Headgear-Mounted (Airstream) PAPR System to protect miners working on its continuous miner sections. The Airstream provides a constant flow of filtered air to protect against potential exposure to respirable coal mine dust during normal mining conditions inby the last open crosscut. The Airstream is being discontinued by the manufacturer, no replacement components will be available, and there are no other MSHA-approved units.

2.    The Versaflo TR-800 PAPR with motor/blower and batte1y qualifies as

intrinsically safe, based on reports by the International Electrotechnical Commission Systems for Certification to Standards Relating to Equipment for Use in Explosive Atmospheres (IECEx). The blower is certified by Underwriter Laboratories (UL) with an intrinsically safe rating of Division 1: Class I, II, III; Division 1: Groups C, D, E, F, G; T4 under the current standard of UL 60079; ATEX-certified with a rating of “ia.” The Versaflo TR-800 is rated and marked “Ex ia I MA, Ex ia IIB T4 Ga, Ex ia IIIC 135oC Da; -20oC � TA � +55oC.”
3.    The Versaflo TR-800 PAPRs provide a constant flow of air inside the headtop or helmet. This airflow provides respiratory protection and comfort in hot working conditions.

4.    The Versaflo TR-800 is not MSHA-approved as permissible, and 3M is not currently pursuing MSHA approval.

5.    The alternative method in the petition will at all times guarantee no less than the same measure of protection afforded to the miners by the mandatory standard.

The petitioner’s alternative method addresses training, inspections, examinations and records, servicing, continuous monitoring for methane and procedures when 1.0 percent or more methane is detected, battery chargers, battery charging and change out procedures, and special precautions for lithium batteries. These proposed terms and conditions for the use of Versaflo are consistent with those approved by MSHA for previous petitions.

The petitioner states the PAPRs will not be used at the end of their life cycle. “The battery must not be used at the end of its life cycle (i.e., when there is a performance decrease of greater than 20% in battery-operated equipment). The battery must be disposed of properly.” The electrolyte used in Lithium-ion batteries is volatile and can ignite under certain circumstances, including overcharging. MSHA requires inclusion of this additional condition to reduce the possibility of thermal runaway, and a subsequent fire or explosion caused by a battery self-igniting.

MSHA personnel investigated the merits of the petition and filed a report of their findings with the Administrator for Mine Safety and Health Enforcement. After a careful review of the entire record, including the petition and MSHA's investigative report, the Administrator issues this Proposed Decision and Order.

Findings of Fact and Conclusions of Law

MSHA started an investigation for pertinent details of the petition on January 29, 2025 at the Buchanan Mine #1. This investigation included an item-by-item review of the proposed petitions, equipment manufacturer’s user instructions, Versaflo TR-800 brochures, and an onsite mine visit. During the onsite visits, the MSHA investigator verified that the proposed Petitions for Modifications (PFM) were posted on the mine’s bulletin board and explained the PFM process and all stipulations to the miners and supervisors.

The following individuals participated in the January 29, 2025, investigation on behalf of Buchanan Minerals, LLC:
1.    Barry Matney, Dust Coordinator
2.    Chris Mullins, Respirable Dust Manager

There are no Miner Representatives at Buchanan Minerals, LLC and they are not union affiliated.
Below are descriptions of each mine during this investigation:

Buchanan Minerals, LLC – Buchanan Mine #1 (44-04856) has fifteen (15) shaft openings into the Pocahontas No. 3 seam. The mine is ventilated with fifteen (15) fans (7 exhausting and 8 blowing) producing 2,698,503 CFM air quantity. The mine liberated 5,761,061 cubic feet of methane within 24 hours based on MSHA’s last total liberation sample taking on November 05, 2024. This mine has two (2) longwalls, two (2) super sections and five (5) single continuous miner sections with eleven (11) Mechanized Mining Units (MMU) producing. As of January 29, 2025, there are six hundred and nineteen (619) underground miners.
During the investigation there were approximately two hundred and one (201) miners on the three (3) shifts that were solicited for comments. Although several had comments, no negative comments were voiced concerning use of the non-MSHA approved PAPRs in areas requiring approved permissible electrical devices.

On January 29, 2025, and February 5, 2025, tests were performed by MSHA Inspectors to determine if there was any electromagnetic interference that effected the functionality of the electrical components worn by miners by the 3M Versaflo TR-800 PAPR at the mines listed. The tests were conducted at the following locations:

1)    18 East section (019-0 MMU): Joy Continuous Mining Machine (CMM) (Model: 14CM15, Serial #JM6815B) with Matrix Proximity Detection System, CSE Methane Monitor, and Joy Remote Control

2)    Northeast Mains section (013-0 MMU): Bucyrus 25M-3 Continuous Mining Machine (CMM) (Model: 25M-3, Serial# 371755R) with Strata Proximity Detection System, CSE Methane Monitor and Forced Potato Remote Control

3)    15 East section (017-0 MMU): Long Wall Shear (Model: 7LS01D) and Shields 7LS Shear Control, CSE Methane Monitors (Head Gate, Mid-face and Tail Gate) and ASGS Shield Control.

The investigator first performed baseline functionality tests for all electrical equipment including the PAPR by operating them individually away from one another. Testing was then conducted by positioning the running PAPR in various orientations and distances ranging from zero inches to 4 feet from miner-worn or carried battery powered electrical equipment.

Electrical Equipment typically worn, carried or used. The 3M Versaflo TR-800 had no effect on the performance of any of these devices when tested.

Table 1
Equipment Manufacturer Model No. Approval No.

Versaflo

Interference Yes/No

Strobe Light Koehler 10K-221XX 18-A200001-0 No
MultiGas Detector MSAAltair Altair4X 22-A130001-0 No
CordlessCap Light , ,Visdom ,,V iseLite2 19-A160002-0 No
Cordless Cap Light Koehler Li-8000-xl 19-A230001 No
Corded CapLight Koehler Wheat LI-16 19-A040001-0 No
Methane Monitor CSE 140B-LD 32A-15MS No

ContinuousMining

Machine Remote Control

Joy TX3 2G-4096-0 No

Continuous Mining

Machine Remote Control

Forced Potato 2G-4137-0 No

Longwall Remote Shear

Conh·oller

Joy

XRl Handheld Transceiver

18-A070006-0

No
Shield Conh·olUnit Tiefenbach

Tibatron ASG 5

18-ISA100003

No
Sheild KH Light KH Conh·ols LX2 18-ISA100004 No
CPDM

Thermo Fisher

Scientific

3700-Al 18-A140015-0 No
Dust Pump Escort ELF 2G-924-1 No
Proximity Device Matrix Design Group 18-PDA130003-0 No
Proximity Device Strata Hazardavert 18-PDA090003-0 Yes
Mine Phone Gaih·onics Femco 9B-155-0 No
Mine Radio Kenwood TK 290 23-A150003-0-0 No

Tracking WiredReader

Battery Pack

AMR MN 6020 23-A090013-0 No
Tracking WiredReader AMR MN 6020 23-A090013-0 No
Tracking Hat Tag AMR 23-A070007 No
AMS Sensor AMR MC-6410-HW No

The 3M Versaflo TR-800 had a noticeable effect on the Strata Miner-Wearable Component (MWC). When the 3M Versaflo TR-800 was bought within six (6) inches of the MWC, the MWC would flash and give an audible warning as though it was in the 3 warning zone of the CMM. However, when the MWC was within six (6) inches of the
3M Versaflo TR-800, the CMM’s (Bucyrus 25M-3, S/N 371755R) PDS operated normally during testing.

Each time it was tested, the CMM’s PDS would flash and give the audible alarm in the warning zone, then stop the CMM’s movement when the MWC enter the red zone. The warning and stopping distances were the same whether the 3M Versaflo TR-800 was within 6 inches of the Strata PDS or not.
The miners on the section were observed having the MWC either hooked to their mining belt with a plastic zip-tie or tucked into their coveralls above their mining belt.

Buchanan Mine #1 Mine has two (2) CMM that have the Strata HazardAvert Proximity Detection System installed. All other CMM have the Matrix Proximity Detection System.
The mine has plans to have all CMM use the Matrix Proximity Detection System and eliminate the use of the Strata HazardAvert Proximity Detection System. Currently, there is not a timeframe for when this change will occur. The two (2) CMM in service using the Strata Proximity Detection System are on the 001-0 MMU, 4 South Headgate, Joy Model 14CM25, S/N JM7275 and the 013-0 MMU, Northeast Mains section, Bucyrus Model 25M-3, S/N 371755R.

The Strata HazardAvert Proximity Detection System has been previously identified as being susceptible to electromagnetic inference (EMI) as stated in Strata Worldwide Technical Alert No. 0017. Technical Alert No. 0017 states a minimum distance of 6 inches separation should be maintained between the Personal Alarm Devices (PADs) and other devices such as respirable dust monitors, methane monitors, radios, and trailing cables. The 3M Versaflo TR-800 is available with backpack attachment as well as belt attachment to offer wearers alternative locations to place the power unit.

No other Continuous Mining Machine (CMM) devices were affected by electromagnetic interference (EMI) from the 3M Versaflo TR-800 during these tests.

The Versaflo TR-800 features a helmet with a visor that flips up, connected by a hose to the fan motor/ battery pack which mounts on a belt.

The petitioner alleges that the alternative method proposed in the submitted petition will, at all times, guarantee no less than the same measure of protection afforded by the standard.

Intrinsic Safety Description

Information regarding the UL listing for the Versaflo TR-800 and the CleanSpace EX PAPRs was previously submitted to the MSHA Approval and Certification Center (A&CC). A review was requested for the use of these unapproved PAPRs in areas of mines where permissibility is required. A&CC conducted the reviews and concluded that:
1.    The Versaflo TR-800 PAPR is certified by UL according to the ANSI/UL 60079-11 standard. The UL certificate allows 3M to mark the device as “Ex ia I”, meaning that the unit is certified to be used in hazardous locations (“Ex”), has met the most onerous level of intrinsic safety protection (“ia”), and the Equipment Protection Level (“very high”) is acceptable for use in mines susceptible to firedamp (“I”). Due to legal and regulatory constraints, the UL certificate alone is not sufficient approval.

2.    The CleanSpace EX is certified by TestSafe Australia (TSA) according to the International Electrotechnical Commission (IEC) 60079-0:2011 (General Requirements) and IEC 60079-11:2011 (Intrinsic Safety) standards. The certificate allows PAFtec to mark the device as "Ex ib IIB T4 Gb" and "Ex ia I Ma." Due to legal and regulatory constraints, the TSA certificate is not accepted by MSHA as evidence that the PAPR is approved for use in U.S. mines.

Like the Versaflo TR-800, the CleanSpace EX is certified to be used in hazardous locations, meets the most onerous level of intrinsic safety protection, is acceptable for use in mining locations, the Equipment Protection Level is "very high", appropriate for use in mines susceptible to firedamp. In addition, its security is sufficient that it is unlikely to become an ignition source in normal operation, during expected malfunctions, or during rare malfunctions, even when left energized in the presence of an outbreak of gas (“Ma”).

NIOSH researchers, in a paper titled “An Evaluation of the Relative Safety of U.S. Mining Explosion-Protected Equipment Approval Requirements versus those of International Standards”, have determined that equipment which meets two-fault intrinsic safety as defined in the ANSI/UL 60079 standard would provide at least an equivalent level of safety as that provided by equipment approved to MSHA criteria.

The UL certifications, TSA certifications, and 3M and PAFtec listing materials (drawings, certificate and text report) were found to support the conclusion that both the Versaflo TR-800 and the CleanSpace EX meet the ANSI/UL standard’s “two fault” intrinsic safety requirements for mining equipment.

The Versaflo TR-800 carries an ingress protection rating of IP64. The CleanSpace EX carries an ingress protection rating of IP66. Both ratings exceed the minimum rating of IP54 required by the ANSI/UL and IEC standards for intrinsically safe mining equipment.

Electromagnetic Interference Investigation

Review of the submitted materials indicate that both units, as unintentional radiators, have been tested and found to meet Federal Communications Commission (FCC) Title 47, Code of Federal Regulations, Part 15 requirements for digital devices for use in typical industrial environments. This means that, under the test conditions and in industrial environments, they were found to not cause harmful interference.
Nevertheless, MSHA investigators tested the equipment in the mines to determine if PAPR electrical components such as the pump motor or battery create interference when used in close proximity to other electrical equipment.

Conclusion

When operating or working near continuous mining machines equipped with PDS, the manufacturer recommends a minimum separation distance of six inches between PDS MWCs and other electronic equipment to sufficiently reduce or eliminate interference. (See Appendix 1 for example diagrams of proper PAPR and PDS positioning on the body.)

When the PDS manufacturer’s recommendations requiring a six-inch separation between the PDS MWCs and the PAPRs’ battery pack or motor/blower were followed, MSHA testing showed no apparent interference or performance issues between the PAPRs and the electrical equipment tested typically worn, carried, or used on the CMM Sections (as detailed in Table 1 above), except as stated for the Strata Miner-Wearable Component (MWC) .

Miner training should incorporate the importance of adhering to the PDS manufacturer’s recommendations so there is no interference between the PDS and PAPRs.
Based on the investigation discussed above, MSHA determined that the Versaflo TR-800 can be safely used where permissible equipment is required inby the last open crosscut, if the operator follows all the manufacturer’s recommendations and adheres to the Terms and Conditions of the Proposed Decision and Order.
On the basis of the petition and MSHA’s investigation findings, and the foregoing reasons, Buchanan Minerals, LLC is granted a modification of the application of 30C.F.R. § 75.1002(a) at its Buchanan #1 Mine.

ORDER

Wherefore, pursuant to the authority delegated by the Secretary of Labor to the Administrator for Mine Safety and Health Enforcement and pursuant to Section 101(c) of the Federal Mine Safety and Health Act of 1977, 30 U.S.C. § 811(c), it is ordered that Buchanan Minerals, LLC’s Petition for Modification of the - application of 30 C.F.R. § 75.1002(a) in the Buchanan Mine #1 is hereby:

GRANTED, for the operator, who may use the non-permissible Versaflo TR-800 Powered Air Purifying Respirator (PAPR) inby the last open crosscut until such time that MSHA-approved permissible PAPR devices are available, subject to the conditions of this Order:

Terms and Conditions

1.    Affected mine employees must be trained in the proper use and maintenance of the PAPR(s) to be used at the mine, the Versaflo TR-800 and/or the CleanSpace EX, in accordance with established manufacturer guidelines. This training shall alert the affected employees that neither the Versaflo TR-800 nor the CleanSpace EX PAPR is approved under 30 C.F.R. Part 18 and therefore must be de-energized when 1.0 or more percent methane is detected. The training shall also include the proper method to de-energize these PAPRs. In addition to the manufacturer’s guidelines, MSHA requires that mine employees be trained to examine the units before use to determine if any damage to the units exists that would negatively impact intrinsic safety, or any of the stipulations in this petition

2.    The PAPRs, battery packs, all associated wiring and connections must be examined by a qualified person before use to determine if there are any observable defects or damage to the units that would negatively impact intrinsic safety. If any defect or damage is found, the PAPR must be removed from service.

3.    Each PAPR shall be assigned a unique identification number. The operator shall maintain a separate logbook for the Versaflo TR-800 and CleanSpace EX PAPRs.
The logbooks shall be kept with the equipment or in a location with other mine record books and be made available to MSHA upon request. The equipment shall be examined at least weekly by a qualified person as defined in 30 C.F.R. § 75.512-1 and the examination results recorded in the logbook. Since float coal dust is removed by the air filter prior to reaching the motor, the PAPR user shall conduct regular examinations of the filter and perform periodic testing for proper operation of the “high filter load alarm” on the Versaflo TR-800 PAPR, and the “blocked filter” alarm on the CleanSpace EX PAPR. PAPR examination entries may be expunged after one year.

4.    In addition to the “blocked filter” alarm on the CleanSpace EX PAPR, these units have a visual green/red filter indicator that turns red when the filter needs to be replaced. The mine shall stock an adequate supply of new CleanSpace EX filters and pre-filters.

5.    All Versaflo TR-800 and CleanSpace EX PAPRs to be used inby the last open crosscut shall be physically examined by a qualified person as defined in 30 C.F.R.§ 75.151 prior to initial use. Each unit shall be examined by the person to operate the equipment prior to taking the equipment underground to ensure the equipment is used according to the original equipment manufacturer’s recommendations and maintained in a safe operating condition.

The examinations for the Versaflo TR-800 PAPRs shall include:
a.    Check the equipment for any physical damage and the integrity of the case;
b.    Remove the battery and examine for corrosion;
c.    Inspect the contact points to ensure a secure connection to the battery;
d.    Reinsert the battery and power up and shut down to ensure proper connections;
e.    Check the battery compartment cover or battery attachment to ensure that it is securely fastened; and
f.    For equipment utilizing lithium type cells, ensure that lithium cells and/or packs are not damaged or swollen.

The CleanSpace EX PAPR does not have an accessible/removable battery. The internal battery and motor/blower assembly are both contained within the sealed “power unit” assembly and the battery cannot be removed, reinserted, or fastened. Therefore, examination of the CleanSpace EX PAPR should include any indications of physical damage.
The operator is to ensure that all Versaflo TR-800 and CleanSpace EX PAPR units are serviced according to the manufacturer's recommendations. Dates of service shall be recorded in the equipment's logbook and shall include a description of the work performed.

6.    The Versaflo TR-800 and CleanSpace EX PAPR units that will be used inby the last open crosscut shall not be put into service until MSHA has initially inspected the equipment and determined that it is compliant with all the terms and conditions of this Order.

7.    Prior to energizing the Versaflo TR-800 or the CleanSpace EX PAPR inby the last open crosscut, methane tests must be made in accordance with 30 C.F.R. § 75.323(a).

8.    All hand-held methane detectors shall be MSHA-approved and maintained in permissible and proper operating condition. All methane detectors must provide visual and audible warnings when methane is detected in concentrations at or above1.0 percent.

9.    A qualified person shall continuously monitor for methane immediately before and during the use of the Versaflo TR-800 or CleanSpace EX PAPR inby the last open crosscut.

10.    Neither the Versaflo TR-800 nor the CleanSpace EX PAPR shall be used if methane is detected in concentrations at or above 1.0 percent. When 1.0 percent or more methane is detected while the Versaflo TR-800 or CleanSpace EX PAPR is being used inby the last open crosscut, the equipment shall be de-energized immediately and the equipment withdrawn from the area.

11.    In the Versaflo TR-800, use only 3M TR-830 Battery Pack (TR-800 Battery Pack), which meets lithium battery safety standard UL 1642 or IEC 62133. In the CleanSpace EX, use only the CleanSpace EX Power Unit, which meets the same UL or IEC lithium battery safety standards.

12.    Before each shift when the Versaflo TR-800 or CleanSpace EX PAPR is to be used, all batteries and power units for the equipment must be charged sufficiently for the expected usage on that shift. If spare battery packs for the Versaflo TR-800 PAPR are provided, all battery “change outs” must occur in intake air outby the last open crosscut.

13.    The following maintenance and use conditions shall apply to equipment containing lithium-type batteries:
a.    Neither the TR-830 Battery Pack nor the CleanSpace EX Power Unit may be disassembled nor modified by anyone other than permitted by the manufacturer of the equipment.
b.    The TR-830 Battery Pack shall be charged only on the surface of the mine, and only using a manufacturer’s recommended battery charger, such as:

i.    3M Battery Charger Kit TR-641N, which includes one 3M Charger Cradle TR-640 and one 3M Power Supply TR-941N, or,

ii.    3M 4-Station Battery Charger Kit TR-644N, which includes four 3M Charger Cradles TR-640 and one 3M, 4-Station Battery Charger Base/Power Supply TR-944N.
c.    The CleanSpace EX internal battery, which is contained within the power unit assembly, shall be charged only on the surface of the mine, and only using the manufacturer’s recommended battery charger, such as the CleanSpace EX Battery Charger, Product Code PAF-0066.
d.    Neither the TR-830 Battery Pack nor the CleanSpace EX power unit, which contains the internal battery, shall be exposed to water, allowed to get wet, or immersed in liquid. This does not preclude incidental exposure of the TR-830 battery pack or the CleanSpace EX power unit assembly.
e.    Neither the Versaflo TR-800 PAPR nor the CleanSpace EX PAPR, including the internal battery, shall be used, charged, or stored in locations where the manufacturer’s recommended temperature limits are exceeded. Neither the Versaflo TR-800 PAPR nor the CleanSpace EX PAPR shall be placed in direct sunlight nor stored near a source of heat.
f.    Neither the TR-830 battery pack nor the CleanSpace EX PAPR’s internal battery shall be used at the end of its life cycle (i.e., when there is a performance decrease of greater than 20% in battery-operated equipment). The TR-830 battery pack and the CleanSpace EX power unit containing the internal battery must be disposed of properly.

i.    Follow the manufacturer’s recommendations and instructions. Check and monitor each unit’s run time. Observe and notate the initial run time that a new fully charged battery provides for powering the unit. A record of the initial run time and the date shall be made by a trained and competent person. This record shall not be expunged on an annual basis but must be retained until the PAPR and/or the battery is retired from service.

ii.    Routinely check the battery’s charge status.

iii.    Routinely monitor batteries that are approaching the end of their estimated service life.

iv.    Remove the battery from service when the following conditions are met:
a.    The battery run time drops below 80% of the new battery run time, or;
b.    The battery charge time increases significantly.

v.    Follow the storage instructions as recommended by the manufacturer. If the instructions were not followed for a battery stored or otherwise unused for an extended period or the battery has no charge remaining, consider it to be damaged. Do not attempt to recharge it or to use it. Remove it from service and replace it with a new battery.

14.    Personnel engaged in the use of the Versaflo TR-800 and CleanSpace EX PAPRs shall be properly trained to recognize the hazards and limitations associated with the use of the equipment in areas where methane could be present. Affected mine employees shall also be trained to properly position their PDS MWC at least six inches from their PAPR’s battery/motor blower or battery/power unit to prevent interference. (See Appendix 1 for example diagrams of proper PAPR and PDS positioning on the body.) Also, personnel shall be trained regarding proper procedures for donning Self-Contained Self Rescuers (SCSRs) during a mine emergency while wearing the Versaflo TR-800 or CleanSpace EX PAPR. The mine operator shall submit proposed revisions to update the Mine Emergency Evacuation and Firefighting Program of Instruction under 30 C.F.R. § 75.1502.

15.    Within 60 days after this Order becomes final, the operator shall submit proposed revisions for its approved 30 C.F.R. Part 48 training plans to the Mine Safety and Health Enforcement District Manager. These proposed revisions shall specify initial and refresher training regarding the terms and conditions stated in this Decision and Order. When training is conducted on the terms and conditions in this Order, an MSHA Certificate of Training (Form 5000-23) shall be completed. Comments shall be included on the Certificate of Training indicating that the training received was for use of the Versaflo TR-800 or CleanSpace EX PAPR.

16.    All personnel who will be involved with or affected by the use of the Versaflo TR-800 or CleanSpace EX PAPRs shall receive training in accordance with 30 C.F.R.§ 48.7 on the requirements of this Order within 60 days of the date this Order becomes final. Such training must be completed before any Versaflo TR-800 or CleanSpace EX PAPR can be used inby the last open crosscut. The operator shall keep a record of such training and provide such record to MSHA upon request.

17.    The operator shall provide annual retraining to all personnel who will be involved with or affected by the use of the Versaflo TR-800 or CleanSpace EX PAPRs in accordance with 30 C.F.R. § 48.8. The operator shall train new miners on the requirements of this Order in accordance with 30 C.F.R. § 48.5 and shall train experienced miners on the requirements of this Order in accordance with 30 C.F.R. § 48.6. The operator shall keep a record of such training and provide such record to MSHA upon request.

18.    The operator shall post this Order in unobstructed locations on the bulletin boards and/or in other conspicuous places where notices to miners are ordinarily posted, for a period of not less than 60 consecutive days.

Appendix 1 – PAPR and PDS Positioning

When using a PAPR in conjunction with a Proximity Detection System (PDS), ensure that the manufacturers’ instructions are followed. To prevent interference, maintain at least six inches of separation between the PAPR and PDS’s miner wearable component (MWC). The figures below show how miners can wear these devices with belt-worn and neck-supported PAPRs, maintain the recommended separation distances between the PAPR’s battery/motor blower and the MWC, and prevent such interference.

Figure 4. Proper position of the PDS’s MWC when using a belt-worn PAPR.

Figure 5. Proper position of the PDS’s MWC when using a neck-supported PAPR.

Unless specifically mentioned herein, nothing in this Order changes or supersedes the requirements otherwise imposed by the Mine Act, other mandatory standards or regulations, or approved plans.
The petitioner shall include the above terms and conditions in the initial and annual refresher training as required in its approved Part 48 training plans to ensure that miners are aware of the stipulations contained in this petition.
Any party to this action desiring a hearing on this matter must file in accordance with 30 C.F.R. § 44.14 within 30 days. The request for hearing must be filed with the Administrator for Mine Safety and Health Enforcement, 200 Constitution Ave. NW. Suite 3522 Washington, DC 20210.
Any hearing request must contain a concise summary of position on the issues of fact or law to be raised by the party requesting the hearing, including specific objections to the proposed decision. A party other than the Petitioner who has requested a hearing may also comment on all issues of fact or law presented in the petition, and any party to this action requesting a hearing may indicate a desired hearing site.

If no request for a hearing is filed within 30 days after service of this Proposed Decision and Order, the Decision and Order will become final and must be posted by the operator on the bulletin board at the mine.

Dustan W. Crelly 
(Acting) Administrator for
Mine Safety and Health Enforcement

Certificate of Service

I hereby certify that a copy of this proposed decision was served personally or mailed, postage paid, or provided by other electronic means this 3rd day of March 2025_    to:


Josh Honaker Superintendent 
Buchanan Minerals, LLC
P.O. Drawer L 
Oakwood, VA 24631
jhonaker@coronadoglobal.com

Errol Scott Arnett
Safety and Health Specialist

cc:        Marshall R. Moore Chief Mine Inspector
3405 Mountain Empire Rd.
P.O. Drawer 900
Big Stone Gap, VA 24219 
Dminfo@dmme.virginia.gov
 
 

Position the PDS’s MWC when using a belt-worn PAPR

4. Proper position of the PDS’s MWC when using a belt-worn PAPR.

Position the PDS’s MWC when using a neck-supported PAPR.

5. Proper position of the PDS’s MWC when using a neck-supported PAPR.