November 17, 2021 Fatality - Fatality Alert

Lapse in Appropriations

For workplace safety and health, please call 800-321-6742; for mine safety and health, please call 800-746-1553; for Job Corps, please call 800-733-5627 and for Wage and Hour, please call 1-866-487-9243 (1 866-4-US-WAGE).  This website is currently not being updated due to the suspension of Federal government services. The last update to the site was 10/1/2025.  Updates to the site will start again when the Federal government resumes operations.

Accident Report: Fatality Reference

MINE FATALITY – On November 17, 2021, a customer truck driver was electrocuted after the tarping mechanism on the trailer contacted a high-voltage overhead power line.  While exiting the cab of the truck, the victim contacted the energized truck and received a nonfatal electrical shock.  When he tried to reenter the cab of the truck, he was electrocuted.

Accident scene

Best Practices

  • Construct roadways to provide adequate width and clearance between mobile equipment and energized high-voltage power lines, as required by the National Electrical Safety Code.  Evaluate clearances periodically to account for changing physical and environmental conditions.
  • Provide and maintain a safe location for truck drivers to tarp their loads.
  • Check for overhead hazards when raising and lowering truck beds and tarps.
  • If your vehicle contacts an energized power line:
    • Stay in your vehicle.
    • Immediately call for help on a mobile phone or radio.
    • If staying in the vehicle is unsafe, jump away from the vehicle without contacting the vehicle and the ground at the same time.  Once on the ground, hop away from the power line for at least 40 feet.
  • Post readily visible warning signs or signals when overhead hazards exist.

Additional Information

This is the 32nd fatality reported in 2021, and the 15th classified as “Powered Haulage.”